Placing vacuum traps between an apparatus and vacuum source establishes a safe and controlled working system. The glassware protects the pump from the separated solvents while simultaneously preventing vapours from being emitted back into the system. Vacuum traps in reservoir, one piece, or two piece styles also guarantee that personnel will not be exposed to gases produced that could be harmful. Standard sized inlet and outlet stems can snugly fit regular stoppers.

Placing vacuum traps between an apparatus and vacuum source establishes a safe and controlled working system. The glassware protects the pump from the separated solvents while simultaneously preventing vapours from being emitted back into the system. Vacuum traps in reservoir, one piece, or two piece styles also guarantee that personnel will not be exposed to gases produced that could be harmful. Standard sized inlet and outlet stems can snugly fit regular stoppers.


22  results were found

SearchResultCount:"22"

Sort Results

List View Easy View (new)

Rate These Search Results

Catalog Number: (7520-94)
Supplier: Avantor
Supplier Article Number : 7520-94
Description: The SPE-12G PTFE column processors are specially designed PTFE vacuum chambers that allow 12 samples to be run simultaneously. This offers the flexibi...
UOM: 1 * 1 ST


Supplier: Avantor
Description: These glass column processors are specially designed glass vacuum chambers that allow multiple samples to be run simultaneously. The glass chamber all...

Catalog Number: (BOHLB317-60)
Supplier: Bohlender
Supplier Article Number : B317-60
Description: PTFE head with two threaded necks GL14 for connection of hard-walled tubing by means of separately available laboratory screw joints. Connecting nut ...
UOM: 1 * 1 ST


Supplier: KGW (KARLSRUHER GLASTECHN.)
Description: Cold traps are used in conjunction with vacuum pumps to collect condensation produced from humidity or solvents.

Supplier: KGW (KARLSRUHER GLASTECHN.)
Description: Cold traps are used in conjunction with vacuum pumps to collect condensation produced from humidity or solvents. Model KF cold traps have a GL 32 glas...

Catalog Number: (KGWA1702)
Supplier: KGW (KARLSRUHER GLASTECHN.)
Supplier Article Number : 1702
Description: This cold trap is a complete version in which the dewar flask is bonded to the cold trap, because of its design, this version has got two free walls f...
UOM: 1 * 1 ST


Supplier: KGW (KARLSRUHER GLASTECHN.)
Description: These cold traps (cold finger condensers) are constructed in the same way as standard cold traps.

Catalog Number: (KGWA1707)
Supplier: KGW (KARLSRUHER GLASTECHN.)
Supplier Article Number : 1707
Description: Cold traps are used in conjunction with vacuum pumps to collect condensation produced from humidity or solvents and these cold traps can be used for m...
UOM: 1 * 1 ST


Catalog Number: (KGWA17380-NW16)
Supplier: KGW (KARLSRUHER GLASTECHN.)
Supplier Article Number : 17380-NW16
Description: Simple cold traps, which are also known as cold finger condensers, are used in conjunction with vacuum pumps and the condensation Produced from humidi...
UOM: 1 * 1 ST


Supplier: Lenz Laborglas GmbH & CO.KG
Description: For direct filling with coolant. Double-walled design ensures low coolant consumption. Includes NS 29/32 standard ground socket for connecting to the ...

Catalog Number: (KGWA17407)
Supplier: KGW (KARLSRUHER GLASTECHN.)
Supplier Article Number : 17407
Description: Type S cold trap has a conical ground joint NS 45/40 as connection part. The condensation area can be separated from the upper section of cold trap. T...
UOM: 1 * 1 ST


Catalog Number: (KGWA17410-NW16)
Supplier: KGW (KARLSRUHER GLASTECHN.)
Supplier Article Number : 17410-NW16
Description: Made from borosilicate glass 3.3, in compliance with DIN/ISO 3585.
UOM: 1 * 1 ST


Supplier: PerkinElmer
Description: Air monitoring trap, TurboMatrix

Supplier: KIMA SAS DI CHIARIN RENZO & C
Description: ESA 1 single use holder, PP

Supplier: VARIAN
Description: Though highly stabilised, it is impossible to guarantee that no particles will dislodge from the column wall. When used in valve-switching application...

Supplier: EDWARDS HIGH VACUUM (METTLER)
Description: Inlet Desiccant Trap IDT20K: Use when pumping limited quantities of water vapour at high pumpings speeds to a low vapour pressure.

Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at 1-800-932-5000.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at 1-800-932-5000.
This product is marked as restricted and can only be purchased by approved Shipping Accounts. If you need further assistance, email VWR Regulatory Department at Regulatory.affairs.ch@vwr.com
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
This product has been blocked by your organization. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
Product(s) marked with this symbol are discontinued - sold till end of stock. Alternatives may be available by searching with the VWR Catalogue Number listed above. If you need further assistance, please call VWR Customer Service on 044 745 13 13
1 - 16 of 22
no targeter for Bottom